Fire Rated Steel Doors

Fire Rated Steel Doors

Vulcan Fire Rated Steel Doors (Hollow Metal Doors) are designed for all the residential, commercial and industrial applications. Vulcan Fire rated Steel Doors are made out of Double skinned galvanized steel as Hollow Metal Doors with honeycomb or Rockwool Infill which provides insulation. Available in both Single and Paired Configurations. Vulcan fire rated steel doors offer a highest degree of fire compartmentation, acts as a barrier to prevent fire spread, provides a safe egress in case of fire.

As one of the top-rated quality manufacturer in the region, we provide different variants of quality fire doors like Panic Exit Doors, Thermal Insulated Doors, and Vision Lite Doors & Flame & Fire Stop Doors.

Fire Rated Steel Doors

Technical Data Sheet

Frames Frames are made out of high-quality Steel. Steel frames are made out of ASTM Grade GI Sheet of thicknesses either 1.5mm/1.8mm/2.0mm. Vulcan profiled Steel Frames are strong enough for the increased level of protection and carries high quality finish with its perfect welding techniques, which leaves with perfect corners, anchor bolt reinforcements .All Frames are manufactured with specified ironmongery reinforcements.
Shutters Shutters are made out of ASTM grade GI Steel with standard/tested thickness of 1.2mm. Shutters are made with Honeycomb/Rockwool with Steel Stiffeners providing the thermal insulation. Shutters can be provided in different variants like flush, vision lite, single leaf or double leaf.
Glazing Door glazing could be provided as per the customer requirement or tested specifications with Fire Rated Glass for Fire Rated Doors or Georgian wired Glass for non-fire rated doors. Vulcan Fire Rated Doors are certified with 186 Sq. In Glass for 3 hours.
Hardware Fire Rated/Tested Hardware complying to UL/ANSI, BS/CE can be accommodated.
Fire Ratings 20 minutes to up to 240 minutes. Bigger pane area in ANSI doors (186 sq.in). Available in BS and UL (ANSI) Standards.
Sizes Customized sizes available (contact us for more details).
Tested & Certified ANSI/UL 10B – Fire Test Assemblies, ANSI/UL10C – Positive Fire Test for Assemblies, BS 476 P22 1987-Fire tests on building materials and structures. Method for determination of the fire resistance of non-loadbearing elements of construction.
Types of Doors Fire Exit Doors, Interior Doors, Exterior Doors, Hollow Metal Doors, Fire Proof Doors, Security Doors, Vision Lite Doors, Louver Doors, Transom Panel Doors, Acoustic Doors / Sound Proof Doors, Radiation Protection Doors / X Ray Protection Doors, Anti-Bacterial Doors
Recommended Use Commercial Buildings, Residential Buildings, Warehouses, Labor Camps, Public Areas-Tunnels, Parks etc, Hospitals, Government Buildings, Airports / Seaports / Metro Stations